Description
Product Details:
Brand Name: SAFESAVE
Model Number: SJR3-2055
Rated power: 90kW
Type: Three phase 660V
Inbuilt bypass: NO
Frequency: 50/60hz
Packing Dimension: 65*39*38cm
G.W: 20.5kg
Warranty: 18 months
Product Overview:
SJR3-2000 90kw 660V series motor soft starter is the latest developed by our company. It expands new functions such as literal display, industrial communication and various protections based on the products of SJR2 series softstarter. This product will be the upgrading and replacement of SJR2 series ac motor soft starter eventually. It shares the same technical framework with SJR3-3000 motor soft starter.
Protection function:
SJR3-2000 series soft starter possesses complete protection functions to protect the operation security of the soft starter and the motor. During operation, the protection level and protection parameters should be properly set based on different circumstances.
◎ Over-heating protection of the soft starter: the protection will start when the temperature rises to 80℃±5℃, and it will stop when the temperature falls to 55 C(lowest).
◎ Delayed time of input phase loss protection: <3s
◎ Delayed time of output phase loss protection: < 3s.
◎ Delayed time of input three-phase unbalance protection: 3. Taking the deviation of current in each phase is over 50+10%as the criteria. when the load current is less than 30% of the nominal rated value of the soft starter. it is confirmed that the deviation will Increase.
◎ Protection time of over-current during starting: the protection time shall be continued to be longer than 5 times of the maximum operating current of code F5, see table P16: 9-2-1.
◎ Protection time of overloading in running: inverse time limit thermal protection shall be provided based on the maximum operating current of code F6, see the tripping protection time curve(figure 9-3-1).
◎ Delayed time for power under-voltage protection: when the power voltage is under the extreme value 40%o, the protection times 0.5s, when the power voltage is below the set value, the protection time< 3s.
◎ Delayed time for power over voltage protection: when the power voltage is over the extreme value 130%, the protection time< 0.5s, when the power voltage is over the set value, the protection time< 3s
◎ Delayed time for load short circuit protection<0 Is, if the current is more than 10 times of the nominal rated value of the soft starter, this protection shall not replace the fuse or short circuit protection device.
The above time parameters are the periods from the valid signal being detected to the tripping protection directive being given; these parameters are for information only. In the event that the protection functions of the soft starter fails to meet the requirements of customers, special protection devices should be installed to ensure the safety.
Rated power of SJR3-2000 series motor softstarter
Dimensions of SJR3-2000 series motor softstarter:
Application of SJR3-2000 series motor softstarter:
Certificate:
Reference for application fields
Application of mechanical type | load type | The executive ability of SJR3 | Starting current(%) | Starting time(s) |
Centrifugal pump | Standard load | Slow shutdown protection(to eliminate water hammer), under-load protection or protection against phase inversion | 300 | 5-15 |
Piston pumo | Standard load | Run test.Control of no-lubrication run and pump rotation direction. | 350 | 5-15 |
Fan | Standard load, heavy load if>30s | Having detected overload or under load caused by blockage, it will provides braking torque.(click on fan to interrupt drive) | 300 | 10-40 |
Shrink machine | Standard load | Motor protection, the motor can also provide special | 300 | 5-10 |
Screw compressoe | Standard load | Provides protection against phase reversal,and is used for automatic discharge of contact when the machine is stopped | 350 | 3-20 |
Centrifugal compressor | Standard load, heavy load if>30s | Provides protection against phase reversal,and is used for automatic discharge of contact when the machine is stopped | 300 | 10-40 |
Piston compressor | Standard load | Provides protection against phase reversal,and is used for automatic discharge of contact when the machine is stopped | 350 | 5-10 |
The transmission belt/ transmission machine | Standard load | The process control of fault detection or the under-load control of the circuit | 350 | 3-10 |
Spiral crane | Standard load | Overload control of harsh environment detection | 300 | 3-10 |
T-cable car | Standard load | Overload control of blockage detection | 300 | 2-10 |
Elevator | Standard load | Overload control of blockage detection.Constant start of varying load | 400 | 5-10 |
Saw/band | Standard load | Fast stop brake | 300-350 | 5-60 |
Crusher/chip cutting machine | Heavy load | Control starting torque | 400 | 3-10 |
Blender | Standard load | Current display,indication of product density | 350 | 5-20 |
Mixer | Standard load | Current display | 350 | 5-10 |
Lapping machine | Heavy load | The vibration is limied when the machine is stopped.Overload control of blockage detection | 450 | 5-60 |
Crushing machine | Standard load | The vibration is limied when the machine is stopped.Overload control of blockage detection | 400 | 10-40 |
Refining machine | Standard load | Control starting and stop torque | 300 | 5-30 |
Press | Heavy load | Increase working cycle brake | 400 | 20-60 |
Tracting lift | Standard load | Overload control of blockage detection or under load control for the detection of breakpoints | 400 | 2-10 |
Lifting screw | Standard load | Overload control of blockage detection or under load control for the detection of breakpoints | 300 | 3-10 |
Tracting lift | Standard load | Overload control of blockage detection or under load control for the detection of breakpoints | 400 | 2-10 |
Lifting screw | Standard load | Overload control of blockage detection or under load control for the detection of breakpoints | 300 | 3-10 |