90kw Ac Motor Soft Starter

Description

Product Details:
Brand Name: SAFESAVE
Model Number: SJR3-2055
Rated power: 90kW
Type: Three phase 660V
Inbuilt bypass: NO
Frequency: 50/60hz
Packing Dimension: 65*39*38cm
G.W: 20.5kg
Warranty: 18 months

Share:

Product Details

Technical Parameter

softstarter-2 - 副本


Product Overview:

SJR3-2000 90kw 660V series motor soft starter is the latest developed by our company. It expands new functions such as literal display, industrial communication and various protections based on the products of SJR2 series softstarter. This product will be the upgrading and replacement of SJR2 series ac motor soft starter eventually. It shares the same technical framework with SJR3-3000 motor soft starter.

 

Protection function: 

SJR3-2000 series soft starter possesses complete protection functions to protect the operation security of the soft starter and the motor. During operation, the protection level and protection parameters should be properly set based on different circumstances.

◎ Over-heating protection of the soft starter: the protection will start when the temperature rises to 80℃±5℃, and it will stop when the temperature falls to 55 C(lowest).

◎ Delayed time of input phase loss protection: <3s

◎ Delayed time of output phase loss protection: < 3s.

◎ Delayed time of input three-phase unbalance protection: 3. Taking the deviation of current in each phase is over 50+10%as the criteria. when the load current is less than 30% of the nominal rated value of the soft starter. it is confirmed that the deviation will Increase.

◎ Protection time of over-current during starting: the protection time shall be continued to be longer than 5 times of the maximum operating current of code F5, see table P16: 9-2-1.

◎ Protection time of overloading in running: inverse time limit thermal protection shall be provided based on the maximum operating current of code F6, see the tripping protection time curve(figure 9-3-1).

◎ Delayed time for power under-voltage protection: when the power voltage is under the extreme value 40%o, the protection times 0.5s, when the power voltage is below the set value, the protection time< 3s.

◎ Delayed time for power over voltage protection: when the power voltage is over the extreme value 130%, the protection time< 0.5s, when the power voltage is over the set value, the protection time< 3s

◎ Delayed time for load short circuit protection<0 Is, if the current is more than 10 times of the nominal rated value of the soft starter, this protection shall not replace the fuse or short circuit protection device.

The above time parameters are the periods from the valid signal being detected to the tripping protection directive being given; these parameters are for information only. In the event that the protection functions of the soft starter fails to meet the requirements of customers, special protection devices should be installed to ensure the safety.

 

ac motor starter-2



Rated power of SJR3-2000 series motor softstarter

SJR3-2000


Dimensions of SJR3-2000 series motor softstarter:


Application of SJR3-2000 series motor softstarter:

6


Certificate:

7

Reference for application fields

Application of
mechanical type 
load type The executive ability of SJR3Starting current(%)Starting time(s)
Centrifugal pumpStandard loadSlow shutdown protection(to eliminate water hammer),
under-load protection or protection against phase inversion
3005-15
Piston pumoStandard loadRun test.Control of no-lubrication run and pump rotation direction.3505-15
FanStandard load,
heavy load if>30s
Having detected overload or under load caused by blockage,
it will provides braking torque.(click on fan to interrupt drive)
30010-40
Shrink machine Standard load Motor protection, the motor can also provide special 3005-10
Screw compressoeStandard loadProvides protection against phase reversal,and is used for automatic discharge of contact when the machine is stopped3503-20
Centrifugal compressorStandard load,
heavy load if>30s
Provides protection against phase reversal,and is used for
automatic discharge of contact when the machine is stopped
30010-40
Piston compressor Standard loadProvides protection against phase reversal,and is used for
automatic discharge of contact when the machine is stopped
3505-10
The transmission belt/
transmission machine 
Standard loadThe process control of fault detection or the under-load control
of the circuit 
3503-10
Spiral craneStandard loadOverload control of harsh environment detection 3003-10
T-cable car Standard loadOverload control of blockage detection3002-10
ElevatorStandard load Overload control of blockage detection.Constant start of varying load4005-10
Saw/bandStandard loadFast stop brake 300-3505-60
Crusher/chip cutting machine Heavy load Control starting torque 4003-10
Blender Standard load Current display,indication of product density 3505-20
Mixer Standard load Current display3505-10
Lapping machine Heavy load The vibration is limied when the machine is stopped.Overload control
of blockage detection 
4505-60
Crushing machine Standard load The vibration is limied when the machine is stopped.Overload control
of blockage detection 
40010-40
Refining machine Standard load Control starting and stop torque3005-30
PressHeavy load Increase working cycle brake 40020-60
Tracting lift Standard load Overload control of blockage detection or under load control for the
detection of breakpoints
4002-10
Lifting screwStandard loadOverload control of blockage detection or under load control for the
detection of breakpoints
3003-10
Tracting lift Standard loadOverload control of blockage detection or under load control for the
detection of breakpoints
4002-10
Lifting screwStandard loadOverload control of blockage detection or under load control for the
detection of breakpoints
3003-10