Description
Product Details:
Brand Name: SAFESAVE
Model Number: SN360 Series
Power range: 0.75kW~132kW
Input: DC 400v~750V or AC 3 phase, 380v
Output: AC 3 phase, 380V
Smart Control: MPPT
Warranty: 18 months
Video of SN360 Series solar ac drive
Product Overview:
SAFESAVE SN360 Series 400V-750V solar pump frequency inverter is a high quality, multi-function SVC inverter, based on the European power and latest control theoretical and technological achievements and combining with the latest market power technology application requirements. By decoupling control of motor magnetic flux current and torque current torque to reach fast response and accurate control, you can run a wide range of speed and torque control in high-precision.
Product Features:
◎ Control system: AC frequency vector control based the high performance of DSP.
◎ Control method: V/F control, vector control for flux with open loop 1, vector control for flux with open loop 2, vector control for PG.
◎ Lifting function of automatic torque: Torque control for low frequency (1Hz) and great output in the control method of V/F.
◎ Control on accelerating and decelerating: Setting method for subsections of accelerating and decelerating S curve; the longest operation time 9600h.
◎ Control on programme operation: Operation for speed program of 16 sections; the longest operation time: 888.88h.
◎ V/F curve method: User defines V/F curve for linear and multiple power
Rated power of SN360 Series solar water pump vfd:
Single phase 220v input, three phase 220v output
Three phase 380v input, three phase 380v output
Basic submersible solar water pumping system:
Diagram of solar pumping system:
SN360 series solar frequency inverter for irrigation system:
Wiring Diagram of SN360 series solar frequency inverter:
Certificate:
After-sale services:
1 )If the solar pump frequency inverter fails to run in good status, please check first, and then check again by re-reading and referencing this instruction manual.
2)For any fault, please contact with the reseller or the"after-sale services department, office of our company"recorded in the instruction manual.
3)Repair within the warranty: free repair will be provided for any fault caused by the problems of manufacturing. However, all items in the "Prostar Starter Warranty Certificate "should be filled correctly and detailedly, otherwise, the repair will be charged.
4)Warranty expired: under the circumstance that the functions can be maintained after repair, paid repair will be provided as required by customers.
FAQ:
Q: what's the payment term?
A: We accept T/T, L/C, West Union, Cash, etc. Usually, T/T 30% deposit and 70% balance before shipment or against copy of B/L. 100% for at sight LC.
Q: What package standard?
A: For small capacity, we packed with carton, but for big capacity, we can make the pallet or use strong wooden case to distinguish and protect the goods.
Q: What is your production capacity?
A: 3000 sets per month.
Technical specification of SN360 series solar VFD | ||
Input | Input AC voltage(V) | AC380 3PH 380V_-15%) 440V(+10%) |
AC220 Single phase 220v±15% | ||
AC220 3-phase 220V±15% | ||
Maximum input DC bus voltage | 800VDC | |
Recommended DC bus voltage | 540VDC | |
Recommended MPPT range | 450-750VDC(380VDC) | |
260-350VDC(220VAC) | ||
Input current(A) | Refer to the rated value | |
Input current(Hz) | 50Hz or 60Hz,Allowed range:47-63Hz | |
Output | Output voltage(V) | 0~the input voltage |
Output current(A) | Refer to the rated value | |
Output power(kw) | Refer to the rated value | |
Output frequency(Hz) | 0~3200Hz | |
Control | Motor type | Asynchronous motor |
Speed ratio | Asynchronous motor 1:100(SVC) | |
Speed control accuracy | ±0.2%(SVC) | |
Speed fluctuation | ±0.3%(SVC) | |
Torque response | <20ms(SVC) | |
Torque control accuracy | 10%(SVC) | |
Starting torque | 0.25Hz/150%(SVC) | |
Overload capability | 150% of rated current: 1 minute | |
180% of rated current: 10 seconds | ||
200% of rated current: 1 second | ||
Running control | Frequency setting method | Digital setting |
Analog setting | ||
Pulse frequency setting | ||
Multi-step speed running setting | ||
Simple PLC setting | ||
PID setting,MODBUS communication setting | ||
Shift between the set combination and set channel | ||
Auto-adjustment of the voltage | Keep a stable voltage automatically when the grid voltage transients | |
Fault protection | Provide over 30 fault protection functions | |
Overcurrent, overvoltage, undervoltage | ||
Overheating, phase loss and overload etc | ||
Special functions for PV water pumps | Maximum power tracking, pre-warning at weak light(A-LS), auto wake up at strong light; Pre-warning when full water(A-tF),auto wake up at low water level; Underload pre-warning(A-LL) and fault protection of water level sensor(tSF); When pre-warning, the inverter is in stand-by. | |
Peripheral interface | Terminal analog input resolution | ≤20mv |
Terminal switch input resolution | ≤20ms |