Contact Us+8613505873345

Search
Banner

Dc Solar Pump Frequency Inverter

Description

Product Details:
Brand Name: SAFESAVE
Model Number: SN360 Series
Power range: 0.75kW~132kW
Input: DC 400v~750V or AC 3 phase, 380v
Output: AC 3 phase, 380V
Smart Control: MPPT
Warranty: 18 months

Share:

Product Details

Technical Parameter

solar  inverter.jpg    



Video of SN360 Series solar ac drive



Product Overview:

SAFESAVE SN360 Series 400V-750V solar pump frequency inverter is a high quality, multi-function SVC inverter, based on the European power and latest control theoretical and technological achievements and combining with the latest market power technology application requirements. By decoupling control of motor magnetic flux current and torque current torque to reach fast response and accurate control, you can run a wide range of speed and torque control in high-precision.


Product Features:

◎ Control system: AC frequency vector control based the high performance of DSP.

◎ Control method: V/F control, vector control for flux with open loop 1, vector control for flux with open loop 2, vector control for PG.

◎ Lifting function of automatic torque: Torque control for low frequency (1Hz) and great output in the control method of V/F.

◎ Control on accelerating and decelerating: Setting method for subsections of accelerating and decelerating S curve; the longest operation time 9600h.

◎ Control on programme operation: Operation for speed program of 16 sections; the longest operation time: 888.88h.

◎ V/F curve method: User defines V/F curve for linear and multiple power



Rated power of SN360 Series solar water pump vfd:

Single phase 220v input, three phase 220v outputSN360-220V solar inverter


Three phase 380v input, three phase 380v output

SN360-380V 480v solar vfd



Basic submersible solar water pumping system:

solar inverter.jpg



Diagram of solar pumping system:

9.jpg



SN360 series solar frequency inverter for irrigation system:

solar VFD



Wiring Diagram of SN360 series solar frequency inverter:

solar pump inverter.jpg




Certificate:

4



After-sale services:

1 )If the solar pump frequency inverter fails to run in good status, please check first, and then check again by re-reading and referencing this instruction manual.

2)For any fault, please contact with the reseller or the"after-sale services department, office of our company"recorded in the instruction manual.

3)Repair within the warranty: free repair will be provided for any fault caused by the problems of manufacturing. However, all items in the "Prostar Starter Warranty Certificate "should be filled correctly and detailedly, otherwise, the repair will be charged.

4)Warranty expired: under the circumstance that the functions can be maintained after repair, paid repair will be provided as required by customers.



FAQ:

Q: what's the payment term?

A: We accept T/T, L/C, West Union, Cash, etc. Usually, T/T 30% deposit and 70% balance before shipment or against copy of B/L. 100% for at sight LC.

Q: What package standard?

A: For small capacity, we packed with carton, but for big capacity, we can make the pallet or use strong wooden case to distinguish and protect the goods.

Q: What is your production capacity?

A: 3000 sets per month.

Technical specification of SN360 series solar VFD
Input Input AC voltage(V)AC380 3PH 380V_-15%) 440V(+10%)
AC220 Single phase 220v±15%
AC220 3-phase 220V±15%
Maximum input DC bus voltage 800VDC
Recommended DC bus voltage 540VDC
Recommended MPPT range450-750VDC(380VDC)
260-350VDC(220VAC)
Input current(A)Refer to the rated value
Input current(Hz)50Hz or 60Hz,Allowed range:47-63Hz
OutputOutput voltage(V)0~the input voltage 
Output current(A)Refer to the rated value 
Output power(kw)Refer to the rated value 
Output frequency(Hz)0~3200Hz
Control Motor typeAsynchronous motor 
Speed ratio Asynchronous motor 1:100(SVC)
Speed control accuracy ±0.2%(SVC)
Speed fluctuation±0.3%(SVC)
Torque response<20ms(SVC)
Torque control accuracy10%(SVC)
Starting torque0.25Hz/150%(SVC)
Overload capability150% of rated current: 1 minute
180% of rated current: 10 seconds
200% of rated current: 1 second
Running controlFrequency setting methodDigital setting 
Analog setting  
Pulse frequency setting 
Multi-step speed running setting
Simple PLC setting
PID setting,MODBUS communication setting
Shift between the set combination and set channel
Auto-adjustment of the voltageKeep a stable voltage automatically when the grid voltage transients 
Fault protection Provide over 30 fault protection functions
Overcurrent, overvoltage, undervoltage
Overheating, phase loss and overload etc
Special functions for PV water pumps Maximum power tracking, pre-warning at weak light(A-LS), auto wake up at strong light;
Pre-warning when full water(A-tF),auto wake up at low water level;
Underload pre-warning(A-LL) and fault protection of water level sensor(tSF);
When pre-warning, the inverter is in stand-by.
Peripheral interfaceTerminal analog input resolution≤20mv
Terminal switch input resolution≤20ms